Enter/Exit Programming Mode
34
PowerScan™ PD953X/PBT950X/PM950X
ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK charac-
ter from the host following label transmiss
ion. The selectable timeout range
is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A
selection of 0 disables the timeout.
See page 274 for more information on setting this feature.
Select ACK NAK Timeout Value Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
Appendix D, Keypad
repre-
senting your desired character(s). End by scanning
the ENTER/EXIT ba
r code again.
Make a mistake? Scan the CANCEL bar code to abort
an
d not save the entry string. You can then start
again at the beginning.
CANCEL
01 ACK NAK Timeout value is 200ms
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label trans-
mission due to a retry condition. The selectabl
e range is from 1 to 254
retries. A selection of 0 disables the count, and a selection of 255 specifies
unlimited retries. See page 275 for more information.
Select ACK NAK Retry Count Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
Appendix D, Keypad
repre-
senting your desired character(s). End by scanning
the ENTER/EXIT ba
r code again.
Make a mistake? Scan the CANCEL bar code to abort
an
d not save the entry string. You can then start
again at the beginning.
CANCEL
DEFAULT