PM950X-Only Features
Changing System Speed in Normal Mode
1. Link the PM950X with a BC9xxx Base.
2. With the PM950X, read a Compatible Mode programming label on
page 238 to set low, intermediate, or high speed.
3. Place the PM950X into the BC9xxx.
The Reader and Base will now be linked at
the new programmed speed.
This feature can also be programmed us
ing Datalogic Aladdin.
1. On the BC9xxx Base, change the Compatible m
ode parameter to low,
intermediate, or high speed through Aladdin.
2. Place an unlinked PM950X onto the BC9xxx base.
The Reader and base will link with the new
programmed speed.
Bluetooth-Only Features
Bluetooth Pin Code
This option specifies the 4-character or 16-character pin code to be used
for authentication of the Bluetooth link. To set the pin code:
1. Sc
an the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode, then enable "Bluetooth Security Mode" on pa
ge 224.
2. S
pecify the desired pin code length (4 or 16) by scanning the appropri-
ate bar code in "Select PIN Code Length" on
page 224.
3. Determine the desired characters. For example, D254 or
ST
OR12345678135M.
4. Convert the characters to hexadecimal using the ASCII Chart on
the
inside back cover of this manual.
5. Go to page 224 and Scan the bar code: SET 4 CHAR PIN CODE or SET
16-CHAR PIN CODE.
6. Scan the appropriate alphanumeric characters from the keypad in
Appendix D, Keypad, representing the hexadecimal entries determined
in the steps above. You will hear a two-beep indication after the last
c
haracter.
If you make a mistake before the last character, scan the CANCEL bar code
to abort and not save the entry string. You can then start again at the
beginning.