LED and Beeper Indications
Product Reference Guide
317
LED and Beeper Indications
The reader’s beeper sounds and its LED illuminates to indicate various func-
tions or errors on the reader. An optional “Green Spot” also performs useful
fu
nctions. The tables below list these indications. One exception to the
behaviors listed in the tables is that the reader’s functions are programma-
ble, and may or may not be turned on. For example, certain indications such
as the power-up
beep can be disabled using programming bar code labels.
Table 54.
INDICATION DESCRIPTION LED BEEPER
Power-up
Beep
The reader is in the pro-
cess of powering-up.
Reader beeps four
time
s at highest fre-
quency and volume
upon power-up.
Good Read
Beep
A label has been suc-
cessfully scanned by
the
reader.
LED behavior for
this
indication is
configurable via
the feature “
Good
Read: When to
Indicate
The reader will beep
once at
current fre-
quency, volume, tonal
se
tting and duration
upon a successful label
scan.
Green Spot
a
a. Except when in sleep mode or when a
Good Read LED Duration
other than 00 is selected
flashes
mo
mentarily
Upon successful read of
a
label, the software
turns the green spot on
for the time specified by
the configured value.
N/A N/A
Image Cap-
ture
When ready to capture
imag
e
Blue light flashes 2
times when updat-
ing
N/A
LED and Beeper Indications
Table 55. Programming Mode Indications
Programming Mode
- The following indications ONLY occur when the reader is in Pro-
gramming Mode.
INDICATION DESCRIPTION LED BEEPER
Label Program-
ming Mode Entry
A valid programming
label has been scanned.
LED blinks con-
tinuously
Reader sounds
four low frequency
beeps.
Label Program-
ming Mode Rejec-
tion of Label
A label has been rejected. N/A
Reader sounds
t
hree times at low-
est frequency &
curren
t volume.
Label Program-
ming Mode Accep-
tance of Partial
Labe
l
In cases where multiple
labels must be
scanned
to program one feature,
this indication acknowl-
edges each portion as it is
succe
ssfully scanned.
N/A
Reader sounds one
short beep at high-
est frequency &
curren
t volume.

Table of Contents

Other manuals for Datalogic PowerScan PD953X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PD953X and is the answer not in the manual?

Datalogic PowerScan PD953X Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan PD953X
CategoryBarcode Reader
LanguageEnglish

Related product manuals