Code 128
Product Reference Guide
189
Code 128 — cont.
Code 128 Quiet Zones
This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are
blank areas at the ends of a bar code and are typically 10 times the width of the narrowest
bar or space in the label.
ENTER/EXIT PROGRAMMING MODE
Code 128 Quiet Zones = No Quiet Zones
Code 128 Quiet Zones = Quiet Zone on one side
Code 128 Quiet Zones = Quiet Zones on two sides
Code 128 Quiet Zones = Auto
DEFAULT
Code 128 Quiet Zones = Virtual Quiet Zones on two sides

Table of Contents

Other manuals for Datalogic QuickScan i QD2100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan i QD2100 and is the answer not in the manual?

Datalogic QuickScan i QD2100 Specifications

General IconGeneral
Scan speed8 sec/page
Wavelength610 nm
Tilt angle range-65 - 65 °
Decoding standards1D / GS1 DataBar China Post GS1 DataBar Expanded/ Stacked/ Stacked Omnidirectional
Dimensions (WxDxH)170 x 66 x 71 mm
Standard interfacesRS-232, USB, Keyboard wedge
Input voltage5 V
Power consumption340 mA
Product colorWhite
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Weight121.9 g