About Your System 23
Viewing Status Messages
If a system error occurs, the LCD screen will turn amber. Press the Select
button to view the list of errors or status messages. Use the left and right
buttons to highlight an error number, and press Select to view the error.
Removing LCD Status Messages
For faults associated with sensors, such as temperature, voltage, fans, and so
on, the LCD message is automatically removed when that sensor returns to a
normal state. For other faults, you must take action to remove the message
from the display:
Clear the SEL — You can perform this task remotely, but you will lose the
event history for the system.
Power cycle — Turn off the system and disconnect it from the electrical
outlet; wait approximately 10 seconds, reconnect the power cable, and
restart the system.
NOTE: The following LCD status messages are displayed in the Simple format. See
"Setup Menu" on page 16 to select the format in which the messages are displayed.
Table 1-1. LCD Status Messages
Code Text Causes Corrective Actions
E1000 Failsafe
voltage
error.
Contact
support.
Check the system event log
for critical failure events.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 195.
E1114 Ambient Temp
exceeds
allowed
range.
Ambient temperature
reached a point outside the
allowed range.
See "Troubleshooting
System Cooling
Problems" on page 167.
book.book Page 23 Thursday, February 18, 2010 2:06 PM

Table of Contents

Other manuals for Dell PowerEdge R810

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge R810 and is the answer not in the manual?

Dell PowerEdge R810 Specifications

General IconGeneral
Form Factor2U rack server
ChipsetIntel 7500 chipset
Memory Slots32 DIMM slots
ProcessorUp to four Intel Xeon 6500/7500 series processors
MemoryUp to 512GB (32 DIMM slots): 1GB/2GB/4GB/8GB/16GB DDR3
StorageUp to six 2.5" SAS or SATA drives
RAID ControllerPERC H700, PERC H800
NetworkFour embedded Broadcom NetXtreme II 5709c Gigabit Ethernet NICs
Power SupplyRedundant 1100W or 750W AC power supplies
Expansion Slots6 x PCIe Gen2 slots (3 x x8, 3 x x16)
Operating System SupportRed Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi

Related product manuals