8 Settings
Installation and Operation Manual for Inverter RPI M50A_12s V1 EU EN 2017-03-09
76
8.2 "Inverter info." menu area (current set-
tings)
Overview
This function allows you to display the current inverter settings.
Setting options
None.
Menu item path
Main menu > Inverter Info.
Displaying the inverter information
E-Today: 0kWh
Power: 0W
Status: On Grid
10.Sep 2014 15:32
1. If the default information is displayed, press any button to open the main menu.
Otherwise, press the
EXIT
button repeatedly until the main menu is displayed.
Inverter Info.
Event Log
Energy Log
Meter
2. Use the and buttons to select the Inverter Info. entry and then press the
ENT
button.
3. Use the and buttons to page through the list.
Notice: Some list items contain sub-items with additional information.
4. Press the
EXIT
button to exit the menu.
Overview of displayed information
Displayed information Description How can I change this setting
COMM 1.29 ID: 1
DSP 1.44 Red. 1.24
Install:
S/N:xxxxxxxxxxxxx
S/N: xxxxxxxxxxxxx
The 13-character serial number of the inverter.
The serial number is also located on the type
plate of the inverter.
This setting cannot be changed.
Install:
The installation date of the inverter
This setting cannot be changed.
DSP 1.44, RED. 1.24, COMM 1.29
The version numbers of the installed firmware.
This manual relates to the three firmware ver-
sions listed here.
This setting cannot be changed.
ID: 1
The inverter ID. This is required in order to
uniquely identify an inverter when several
inverters are installed in a system.
See “8.4 “Installation settings” menu area”,
page 83 for a detailed description and how
to change the settings
Baud Rate: 19200bps
Insulation: 250k
UK G59-3 230
Country:
Country: GERMANY LV
The configured country or grid type.
See “8.4.3 Country”, page 86 for how to
change the settings
Insulation: 250k
The insulation resistance.
See “8.4.2 Insulation”, page 84 for a
detailed description and how to change the
settings
Baud rate: 19200bps
The RS485 baud rate.
See “8.3.3 Baud rate”, page 80 for a
detailed description and how to change the
settings

Table of Contents

Other manuals for Delta RPI M50A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta RPI M50A and is the answer not in the manual?

Delta RPI M50A Specifications

General IconGeneral
BrandDelta
ModelRPI M50A
CategoryInverter
LanguageEnglish

Related product manuals