Chapter 13 Warning CodesMS300 (High Speed Model)
13-1
Chapter 13 Warning Codes
Model name of digital keypad: KPMS-LE01
ID No. Display Descriptions
1
Modbus function code error (Illegal function code)
Corrective Actions
Check if the function code is correct.
(Function code must be 03, 06, 10, 63)
2
Modbus data address is error (Illegal data address (00 H to 254 H)
Corrective Actions
Check if the communication address is correct.
3
Modbus data error (Illegal data value)
Corrective Actions
Check if the data value exceeds max. / min. value.
4
Modbus communication error (Data is written to read-only address)
Corrective Actions
Check if the communication address is correct.
5
Modbus transmission time-out
6
Keypad transmission time-out
7
Keypad COPY error 1
Keypad simulation error, including communication delays, communication
error (keypad received error FF86) and parameter value error.
8
Keypad COPY error 2
Keypad simulation done, parameter writes error.