Managing End Devices Sleep examples
XBee/XBee-PRO ZigBee RF Modules User Guide 100
Example 1
Configure a device to sleep for 20 seconds, but set SN such that the On/Sleep line will remain de-asserted for up
to 1 minute.
The following settings should be configured on the end device.
SM = 4 (cyclic sleep) or 5 (cyclic sleep, pin wake)
SP = 0x7D0 (2000 decimal). This causes the end device to sleep for 20 seconds since SP is measured in units of
10ms.
SN = 3. (With this setting, the On/Sleep pin will assert once every 3 sleep cycles, or when RF data is received)
SO = 0
All router and coordinator devices on the network should set SP to match SP on the end device. This ensures that
RF packet buffering times and transmission timeouts will be set correctly.
Since the end device wakes after each sleep period (ATSP), the SN command can be set to 1 on all routers and the
coordinator.
Example 2
Configure an end device to sleep for 20 seconds, send 4 IO samples in 2 seconds, and return to sleep.
Since SP is measured in 10ms units, and ST and IR are measured in 1ms units, configure an end device with the
following settings:
SM = 4 (cyclic sleep) or 5 (cyclic sleep, pin wake)
SP = 0x7D0 (2000 decimal). This causes the end device to sleep for 20 seconds.
SN = 1
SO = 0
ST = 0x7D0 (2000 decimal). This sets the sleep timer to 2 seconds.
IR = 0x258 (600 decimal). Set IR to a value greater than (2 seconds / 4) to get 4 samples in 2 seconds. The end
device sends an IO sample at the IR rate until the sleep timer has expired.
At least one analog or digital IO line must be enabled for IO sampling to work. To enable pin 19 (AD1/DIO1) as a
digital input line, the following must be set:
D1 = 3
All router and coordinator devices on the network should set SP to match SP on the end device. This ensures that
RF packet buffering times and transmission timeouts will be set correctly.
Example 3
Configure a device for extended sleep: to sleep for 4 minutes.
SP and SN must be set such that SP * SN = 4 minutes. Since SP is measured in 10ms units, the following settings
can be used to obtain 4 minute sleep.
SM = 4 (cyclic sleep) or 5 (cyclic sleep, pin wake)
SP = 0x7D0 (2000 decimal, or 20 seconds)
SN = 0x0B (12 decimal)
SO = 0x04 (enable extended sleep)
With these settings, the module will sleep for SP * SN time, or (20 seconds * 12) = 240 seconds = 4 minutes.