API operation Sending public profile commands with the API
XBee/XBee-PRO ZigBee RF Modules User Guide 152
Register Joining Device
Frame type: 0x24
Frame Fields Offset Example Description
Start Delimiter
0
Length
MSB 1
LSB 2
Frame-specific
Data
Frame ID
3
Identifies the UART data frame for the host to match with a
subsequent response. If zero, no response is requested.
64-bit Source
Address
MSB 4
Registrant's 64-bit (MAC/EUI64) device address.
5
6
7
8
9
10
LSB 11
Source 16-bit
Address
MSB 12
Registrant's 16-bit device address.
LSB 13
Options
14
Transmit options bitfield.
Unused bits must be set to 0.
0x01 - Disable retries and route repair.
0x20 - Enable APS encryption (if EE=1) Enabling APS encryption
decreases the maximum number of RF payload bytes by 4 (below
the value reported by NP).
0x40 - Use the extended transmission timeout for this destination.
Setting the extended timeout bit causes the stack to set the
extended transmission timeout for the destination address.
Checksum
15