Transmission, addressing, and routing Data transmission
XBee/XBee-PRO ZigBee RF Modules User Guide 58
2 After receiving an OK\r, issue the following commands:
a. ATDH0\r
b. ATDL0\r
c. ATCN\r
3 Verify that each of the three commands returned an OK\r response.
4 After setting these command values, all serial characters will be sent as a unicast transmission to the
coordinator.
Alternatively, if the coordinator's 64-bit address is known, DH and DL can be set to the coordinator's 64-bit
address. Suppose the coordinator's address is 0x0013A200404A2244.
1 Enter command mode (+++).
2 After receiving an OK\r, issue the following commands:
a. ATDH13A200\r
b. ATDL404A2244\
c. ATCN\r
3 Verify that each of the three commands returned an OK\r response.
4 After setting these command values, all serial characters will be sent as a unicast transmission to the
coordinator.