Fault code Cause
F01
Preliminary conditions not satisfied
F08
Calibration taking too long (more than 30 seconds)
F09
User terminated calibration with ESC
F10
Plausibility: "Center position" signal
F11
Plausibility: "Left stop" signal
F12
Plausibility: "Right stop" signal
F13
Plausibility: Calibrated values match
NOTE:
If incorrect values are found, contact your Fendt dealer.
Calibrating VarioGuide steering valve (2403)
WARNING:
Hazard from automatic deflection of the front wheels Risk of injury and death! Material
damage is possible. During calibration check that there are no people or objects within
the steering area!
NOTE:
During calibration, the valve slider free travel is determined.
NOTE:
To operate the automatic track guidance, it is essential to calibrate the steering valve.
Please note:
• Do not leave operator's seat (seat contact
switch).
•
Start engine.
• Tractor stationary.
• Point wheels straight ahead.
• Do not move the steering wheel.
Confirm the warning and fault messages
displayed on the instrument panel with ESC.
Fig. 11
6. VarioGuide components and calibrations
58 VarioGuide
438.020.070.012