G1000 V8.XX S/W Load and Post Install Checkout – Columbia 350/400 Page 3-11
190-00577-04 Revision 1
3.2 Calibration and Activation
3.2.1 Aileron and Elevator Trim Calibration
NOTE
Before conducting the flaps and trim calibration procedure, ensure that the elevator,
elevator trim, aileron and aileron trim systems have been properly rigged and adjusted.
1. Go to the CAL Page Group on the PFD.
2. Select the Flaps and Trim Calibration page (3
rd
page in CAL group), shown below:
Figure 3-1. Aileron and Elevator Trim Calibration
3. This page is protected and requires a keystroke password to perform the calibration. Press the
following softkeys in sequence:
a) softkey 1 (Far Left softkey)
b) softkey 2
c) softkey 3
d) softkey 4
4. Press the Elevator Trim RESET softkey (see Figure 3-1). Press ENT to acknowledge the
following prompt after the RESET softkey is pressed: