Garmin G5 Install Manual & Pilot's Guide
190-02072-00 Rev. E 147
Unit Installation
Installation Manual Pilot's Guide Appendix Index
1.11 PERFORMANCE SPECIFICATIONS/LICENSING/
COMPLIANCE
1.11.1 GPS SPECIFICATIONS
Table 1-35 G5 GPS Specifications
Characteristics Specifications
Acquisition Time
a) Warm Start (position known to 10 nm, time known to 10
minutes, with valid almanac and ephemeris): Less than 5
seconds
b) Cold Start (position known to 300 nm, time known to 10
minutes, with valid almanac): Less than 45 seconds
c) AlwaysLocate™ (with almanac, without initial position or
time): Less than 60 seconds
Update Rate 5 Hz (continuous)
Positional Accuracy < 10 meters
1.11.2 G5 ENVIRONMENTAL SPECIFICATIONS
The G5 has an operating temperature range of -20°C to +60°C. The G5 will prevent
operation from the battery when the battery is outside of this temperature range.