Chapter 3: Programming
32 Concord 4 Installation Manual
Overview
For onsite system programming, you must have an alphanumeric touchpad.
You must use an installer/dealer code (default = 4321) to enter program mode. You
must disarm all partitions before you can place the system into program mode.
Note: If the system is powered up after the programming touchpad is connected or if
a bus command scan is executed, the programming touchpad will be “learned” into
the system and must later be manually deleted.
To enter program mode:
1. Make sure you disarm the system in all partitions.
2. Press 8, 4321, 0, 0. The display shows SYSTEM PROGRAMMING.
To enter program mode using a programming touchpad:
1. Connect the red, black, green, and white wires from the programming touchpad
cable (60-791) to the power and bus wires/terminals on an alphanumeric
touchpad, matching the +12V (red), Bus A (green), Bus B (white), and GND (black)
on each.
2. Make sure the system is powered up and disarmed.
3. Connect the plug on the cable onto the panel programming touchpad header (see
Figure 27 on page 33).
4. Press 8, 4321, 0, 2. The touchpad sounds one short beep. Press * and verify that
the display shows SERVICE TOUCHPAD ACTIVE.
5. Press 8, 4321, 0, 0 and the display shows SYSTEM PROGRAMMING.
6. After programming is complete, disconnect the touchpad from the panel header.

Table of Contents

Other manuals for GE Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 and is the answer not in the manual?

GE Concord 4 Specifications

General IconGeneral
BrandGE
ModelConcord 4
CategorySecurity System
LanguageEnglish

Related product manuals