EasyManuals Logo
Home>gefran>Inverter>ADV200

gefran ADV200 Functions Description And Parameters List

gefran ADV200
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
ADV200 Functions description and parameters list 43
10–MONITORFUNCTION
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
10.1 930 Reference0thr rpm INT16 30 0 CALCI RW FVS
Setting of the threshold for recognition of the speed = 0 reference. The value is valid for both directions of rota-
tion.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
10.2 932 Reference0delay ms UINT16 400 0 10000 RW FVS
Setting of the delay in milliseconds after which the reference = 0 reached signal is enabled.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
10.3 940 Speed0thr rpm INT16 30 0 CALCI RW FVS
Setting of the threshold for recognizing speed value = 0. The value is valid for both directions of rotation.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
10.4 942 Speed0delay ms UINT16 400 0 10000 RW FVS
Setting of the delay in milliseconds after which the speed = 0 reached signal is enabled.
When the motor reaches a speed that is below the zero speed threshold, it stops and the
n= 0
LED lights up.

Table of Contents

Other manuals for gefran ADV200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran ADV200 and is the answer not in the manual?

gefran ADV200 Specifications

General IconGeneral
Brandgefran
ModelADV200
CategoryInverter
LanguageEnglish

Related product manuals