Seivice diagnosis


 
Domestic air conditioner

11.4.2 EEPROM abnormal

Indoor Display E4: indoor EEPROM error
outdoor display F12: Outdoor EEPROM error; Outdoor LED1 flash 1 times
































The Data detected by the EEPROM are used to determine MCU

when the data of EEPROM is error or the EEPROM is damaged

ŶFaulty EEPROM data
ŶFaulty EEPROM
ŶFaulty PCB

* Caution Be sure to turn off power switch before connect or disconnect connector,
or parts damage may be occurred.


Replace the indoor or outdoor mainboard

Method of
malfunction detection
Malfunction detection
conditions
Troubleshooting
Supposed causes
206