7 - Fault finding
98
IntelliTrack
FAULT PROBABLE CAUSE CONTROL/REMEDY
IntelliTrack steers slowly or erratically. Air in system. Vent the Intellitrack cylinders - see Venting the Steering
Hydraulics”
Front potentiometer bar/springs move
erratically.
Re-arrange the spring setup, so that the potentiometer bar
moves freely.
IntelliTrack has non-linear steering or is not
following the tractors track.
Front potentiometer springs are not parallel. Refit springs to parallel position and check potentiometer
reading - see “IntelliTrack Front Potentiometer Calibration.