3 - Description
20
Chem Filler options
The optional HARDI® VACnMIX or HARDI® TURBO FILLER are located on the sprayer’s left side, just behind the MANIFOLD
valves.
HARDI®VACnMIX (optional equipment)
The HARDI VACnMIX™ is used for the mixing of plant protection or
liquid fertiliser chemicals into a solution, and transferring the solution
to Main Tank.
Your Vacuum VACnMIX™ uses the latest design and technology to
provide fast, safe and accurate transfer of liquids, powder or granules.
The Vacuum VACnMIX is a multi-purpose hopper. It is designed for
use in closed system transfer and utilises the tough and reliable Hardi
pump on your sprayer. The rate of transfer is controlled by the
operator.
The VACnMIX is supported on a sturdy lift frame and is equipped with
two vortex mixing jets, a control manifold and a rotating chemical
drum rinse nozzle. The hopper flushing ring is connected to the sight
tube to enable decontamination of both together. The unit has a
water supply inlet port, and a vacuum suction outlet port — for
transfer of either dilute or concentrated liquid chemicals to the spray
tank.
The vortex jets provide vigorous operator-controlled agitation which
mixes granules into solution, or allows liquid chemical concentrate to be pre-mixed. Any granules that do not dissolve are
kept in suspension in the vortex until they disperse.
Featuring a Vacuum and Transfer Valve and an in-line venturi with interchangeable restrictors (based on pump capacity), the
unit can transfer liquid from a clean water source or Envirodrum into the hopper, and from the hopper to the main sprayer
tank.
Vacuum / Transfer Valve (only if equipped with VACnMIX)
This valve is located behind the Chemical Induction Hopper and is used
to control the filling / emptying of the VACnMIX hopper.