3. Parameter setting
3-21
Speed/Torque/
Position control
The signal for controlling the dynamic brake installed outside the servo drive can be output.
* To use this function, set DB MODE (P02-09) parameter first, and set Function No. (20)
to the desired CN1 pin number using P08 menu.
* This function only applies to Special Order products that can connect external DB.
Do not use external DB control
External DB Control Signal Output (Normal Open Type)
External DB Control Signal Output (Normal Close Type)
Speed/Torque/
Position control
When a 17-bit serial encoder is used, the count error detection time of the encoder can be set.
* If P02-40 = 0, the count error alarm function is disabled.
[When using FDA7000EX( Explosion-Proof ) Series]
Speed/Torque/
Position control
Some explosion-proof motor models have a built-in temperature sensor (PTC), and an alarm
(Ano-22) is output when the motor overheats. If you do not use the over temperature alarm
with this sensor, you can disable the alarm function by setting P02-40 = ON.
If P02-40 = ON, the temperature sensor signal of the motor is not connected to the drive,
an alarm (AL-22) will occur.
Enable motor over temperature alarm
Disable the motor over temperature alarm function
[When using FDA7002EX( Explosion-Proof )]
Speed/Torque/
Position control
You can set the overheat alarm detection time of the motor with a built-in temperature sensor.