3. Parameter setting
3-23
P03-08
SC TC 2
Unit
ms
Setting range
0.0 ~ 10000.0
Manufactured
default
By capacity
Speed/position
control
P03-09
Analog CMD TC
Unit
ms
Setting range
0.0 ~ 2000.0
Manufactured
default
0.0
Speed control
P03-10
ACCEL Time
Unit
ms
Setting range
0.0 ~ 90000.0
Manufactured
default
0.0
Speed control
P03-11
DECEL Time
Unit
ms
Setting range
0.0 ~ 90000.0
Manufactured
default
0.0
Speed control
P03-12*
S-Mode TC
Unit
ms
Setting range
0.0 ~ 9000.0
Manufactured
default
0.0
Speed control
P03-13
In Speed Range
Unit
rpm
Setting range
0.0 ~ 9999.9
Manufactured
default
10.0
Speed control
P03-14
Zero Speed Range
Unit
rpm
Setting range
0.0 ~ 9999.9
Manufactured
default
10.0
Speed control
P03-15*
+ 10[V] RPM
Unit
rpm
Setting range
0.0 ~ 9999.9
Manufactured
default
Applied motor
rated speed
Speed/Torque
control
This sets the command speed range of the +10[V] analog voltage when the servo drive is in
speed control or torque control mode.
Set speed
(P03-15)
Voltage