EasyManuals Logo
Home>HIKVISION>DVR>DS-7200 Series

HIKVISION DS-7200 Series User Manual

HIKVISION DS-7200 Series
227 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #172 background imageLoading...
Page #172 background image
User Manual of DS-7200/7300/8100 Series DVR
172
3. Configure the remote alarm host, server port, HTTP port, multicast, RTSP port or telnet.
Alarm Host IP/Port: With a remote alarm host configured, the device will send the alarm event or
exception message to the host when an alarm is triggered. The remote alarm host must have the
CMS (Client Management System) software installed.
The Alarm Host IP refers to the IP address of the remote PC on which the CMS (Client
Management System) software (e.g., iVMS-4200) is installed, and the Alarm Host Port must be
the same as the alarm monitoring port configured in the software (default port is 7200).
Multicast IP: The multicast can be configured to realize live view for more than the maximum
number of cameras through network. A multicast address spans the Class-D IP range of 224.0.0.0
to 239.255.255.255. It is recommended to use the IP address ranging from 239.252.0.0 to
239.255.255.255.
When adding a device to the CMS (Client Management System) software, the multicast address
must be the same as the device’s multicast IP.
RTSP Port: The RTSP (Real Time Streaming Protocol) is a network control protocol designed for
use in entertainment and communications systems to control streaming media servers.
Enter the RTSP port in the text field of RTSP Port. The default RTSP port is 554, and you can
change it according to different requirements.
Server Port and HTTP Port: Enter the Server Port and HTTP Port in the text fields. The
default Server Port is 8000 and the HTTP Port is 80, and you can change them according to
different requirements.
The Server Port should be set to the range of 2000-65535 and it is used for remote client software
access. The HTTP port is used for remote IE access.
Enable Telnet: Telnet function provides an easy way to get access to the DVR. You can see the
advanced information about the device by inputting command; as well the configuration can also
be realized through telnet connection.
Figure 9. 30 Configure More Settings
4. Click the Apply button to save and exit the interface.
9.2.7 Configuring HTTPS Settings
Purpose:
HTTPS (Hyper Text Transfer Protocol Secure) ensures the data transferred is encrypted using Secure Socket
Layer (SSL) or Transport Layer Security (TLS). HTTPS provides authentication of the web site and
associated web server that one is communicating with and creates a secure channel over an insecure network.
HTTPS URLs begin with https:// and use port 443 by default. You can modify the port No. as desired.

Table of Contents