Loading software updates
8
4.3
Loading the software via file selection
Basic - L3P
Release
4.0
11/07
4.3 Loading the software via file
selection
For an update via a file selection window, the Switch software must be on a
drive that you can access via your PC.
Select the Basics:Software dialog.
In the file selection frame, click on "...".
In the file selection window, select the Switch software (switch.bin)
and click on "Open".
Click on "Update" to transfer the software to the Switch.
The end of the update is indicated by one of the following messages:
X Update completed successfully.
X Update failed. Reason: incorrect file.
X Update failed. Reason: error when saving.
After loading successfully, activate the new software: Select the di-
alog Basic Settings:Restart and perform a cold start.
In a cold start, the switch reloads the software from the non-volatile
memory, restarts, and performs a self-test.
In your browser, click on "Reload" so that you can access the Switch
again after it is booted.