114 Xenon/Granit User Guide
The scanner vibrates once when a bar code is successfully read, and twice when a
programming bar code is successfully read. When a programming bar code is
unsuccessful, the scanner emits one long vibration (2 times the Vibrate Duration
length). Scan Vibrate - Good Read Off to keep the scanner from vibrating. Default
= Vibrate - Good Read On.
Vibrate Duration
If you want to set the length for the good read vibration, scan the bar code below,
then set the duration (from 100 - 2,000 milliseconds) by scanning digits from the
Programming Chart, beginning on page 341, then Save. Default = 300 ms.
Beeper Pitch – Error
The beeper pitch codes modify the pitch (frequency) of the sound the scanner
emits when there is a bad read or error. Default = Razz.
Vibrate- Good Read Off
* Vibrate- Good Read On
Vibrate Duration
* Razz (250 Hz)
Medium (3250 Hz)
High (4200 Hz)