124 Xenon/Granit User Guide
piness is decreased, making it less aggressive when reading good quality bar
codes. This setting does not affect 1D bar code reading. Default = Poor Quality PDF
Reading Off.
CodeGate
®
When CodeGate is On, the trigger is used to allow decoded data to be transmitted
to the host system. The scanner remains on, scanning and decoding bar codes, but
the bar code data is not transmitted until the trigger is pressed. When CodeGate is
Off, bar code data is transmitted when it is decoded. Default = CodeGate Off Out-of-
Stand.
Streaming Presentation™ Mode
When in Streaming Presentation mode, the scanner’s aimer goes out after a short
time, but the scan illumination remains on all the time to continuously search for
bar codes. Two modes are available, Normal and Enhanced. Normal mode offers
good scan speed and the longest working ranges (depth of field). Enhanced mode
will give you the highest possible scan speed but slightly less range than Normal
mode. Enhanced mode is best used when you require a very fast scan speed and
don’t require a long working range.
Note: Granit 1980i and 1981i do not support Enhanced Streaming Presentation Mode.
Poor Quality PDF Reading On
* Poor Quality PDF Reading
Off
* CodeGate Off
Out-of-Stand