18 Xenon/Granit User Guide
RS485 Packet Length
If you are using Packet mode, you can specify the size of the data “packet” that is
sent to the host. Scan the Packet Length bar code, then the packet size (from 20 -
256) from the Programming Chart, beginning on page 341, then Save. Default =
40.
USB IBM SurePos
Scan one of the following “Plug and Play” codes to program the scanner for an IBM
SurePos (USB handheld scanner) or IBM SurePos (USB tabletop scanner) inter-
face.
Note: After scanning one of these codes, you must power cycle the cash register.
Each bar code above also programs the following suffixes for each symbology:
USB PC or Macintosh Keyboard
Scan one of the following codes to program the scanner for USB PC Keyboard or
USB Macintosh Keyboard. Scanning these codes also adds a CR suffix.
Packet Length
Symbology Suffix Symbology Suffix
EAN 8 0C Code 39 00 0A 0B
EAN 13 16 Interleaved 2 of 5 00 0D 0B
UPC A 0D Code 128 00 18 0B
UPC E 0A Code 39 00 0A 0B
USB IBM SurePos
(USB Handheld Scanner)
Interface
USB IBM SurePos
(USB Tabletop Scanner)
Interface
U
S
B
K
e
y
b
o
a
r
d
(
P
C
)

Table of Contents

Other manuals for Honeywell XENON 1902G-BF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XENON 1902G-BF and is the answer not in the manual?

Honeywell XENON 1902G-BF Specifications

General IconGeneral
BrandHoneywell
ModelXENON 1902G-BF
CategoryScanner
LanguageEnglish

Related product manuals