66 Library operation
HP StorageWorks Interface Manager card
Figure 45 and Table 9 show and describe the control and indicators located on the FC interface
controller card.
Figure 45 Interface Manager card reset and indicators
Table 9 Interface Manager card reset and indicators
Index
No. Control/indicators Function
1
Green link speed LED On—Port operating at 100 Mbps.
Off—Port is operating at 10 Mbps, or port is
not connected (see link activity LED).
2
Green link activity LED Off—Port disconnected/no link.
On—Port connected to another Ethernet
device.
Flashing—Data is being transmitted or
received.
3
Red LED Green LED
On Off BIOS code failed to run.
Blinks 1x per 5
second interval
Off Hardware POST failed. No firmware images
are loaded.
Blinks 2x per 5
second interval
Off No CompactFlash disk or valid boot sector
image found.
Blinks 3x per 5
second interval
Off Specified firmware image files cannot be
found. Neither the current nor the previous
image was found.
Blinks 4x per 5
second interval
Off Load or execute command failed (boot code
remains at end of process). This indicates
that load, decompress, or execution failed
on both the current and previous image files.
Off Blinks 1x per 5
second interval
Normal state. Load or execute command
succeeded. Boot code successfully loaded,
decompressed, and initiated one of the
image files.
gl01012
1
2
3