Troubleshooting
DynaMAX 550P/560P/575P Waterjet Pump Operator Manual 811390 149
Alarms
The controller monitors the pump while the pump is operating. When the controller senses a
problem that is likely to cause damage to the equipment, the operator interface shows the Alarms
screen. and the beacon light flashes.
Types of alarms
To acknowledge an alarm, touch the screen. The Alarm Log screen opens.
Touch Ack (acknowledge) or Ack All (acknowledge all) on the screen.
The beacon light stops flashing and the alarm screen closes.
Beacon light Intensifier Primary motor Cause of alarm
Warning Amber, flashing Engaged On
The controller
senses a condition
that can cause a
problem or a failure.
Fault 1 Red, flashing Off
On, pump is in
cooling mode
The controller
senses a condition
that will cause a
problem or a failure.
Fault 2 Red, flashing Off Off
The controller
senses a failure
condition.
Fault 3 Red, flashing Engaged On
The Seal
Maintenance
Indicator (SMI)
senses a seal failure
condition.