Troubleshooting
150 811390 Operator Manual DynaMAX 550P/560P/575P Waterjet Pump
Warnings
Alarm Cause Solution
Warning: Battery Error The controller battery is not
operating correctly.
Contact a Hypertherm Technical
Service Associate for information
and support.
Warning: Boost Motor
Warning: Fan Motor
The boost motor or the fan motor
did not start because the thermal
overload relay has tripped.
Reset the relay.
• Find the thermal overload relay
on the motor starter.
• Turn the knob clockwise to the
ON position (I).
• Release the knob. It snaps
counterclockwise to the
OFF
position (O).
• Turn the knob clockwise to the
ON position (I) again.
On Tripped Off
Warning: Too Many Motor Starts
in15 Minutes
Starting and stopping the motor
rapidly can cause damage to the
motor.
Wait longer between stopping and
starting the motor.
Warning: Start Procedure
Hydraulics
Warning: Start Procedure Ramp to
Pierce Pressure
Warning: Start Procedure Ramp to
Cut Pressure
An error occurred during the start
sequence.
• The cutting head is on.
• The bleed-down valve is
leaking.
• The bleed-down valve is not
receiving air.
• The Hydraulics timer setting is
too short.
• Make sure that the cutting head
is off.
• Repair or replace the
bleed-down valve.
• Make sure that the compressed
air supply is on.
• Adjust the timer on the
Start-procedure Timers
screen.
Warning: Hydraulic Fluid >55C The hydraulic fluid is too hot. Refer to Hydraulic fluid on
page 165.
Warning: Left Dynamic Seal
Warning: Right Dynamic Seal
Warning: Left Static Seal
Warning: Right Static Seal
The SMI senses that the
high-pressure seal life remaining is
between 8 hours and 50 hours.
Replace the seal.
Warning: Empty the Dirty Water
Container
The dirty water container is full. Empty the container.