Installation
8
214 811390 Operator Manual DynaMAX 550P/560P/575P Waterjet Pump
Seal Maintenance Indicator
For information about faults and warnings, refer to the Troubleshooting section of this
manual.
Indicator On This turns the Seal Maintenance Indicator (SMI) on or off.
Stop On Fault This turns the Stop On Fault feature on or off.
When this feature is on, the pump operates for 30 minutes after a fault is sensed and
then turns off.
Warning The Seal Maintenance Indicator senses leaks from the intensifier. This value determines
the number of units that cause a warning. The default is 5 units.
Fault This value determines the number of units that cause the system to turn off. The default
is 20 units.
Sleep If a fault occurs and the Stop On Fault feature is not on, this timer determines how long
after a fault is acknowledged that the system pauses before showing the Alarms screen
again. The default is 2.0 hours.