Preventive maintenance
4
DynaMAX 550P/560P/575P Waterjet Pump Operator Manual 811390 79
Check the hydraulic fluid level
Parts, tools, and materials
Do this task when the pump is running.
1. Use a standard screwdriver to remove the pump cover.
2. Make sure that the hydraulic fluid level is at the top mark on the sight gauge. Add hydraulic fluid,
if necessary.
Add hydraulic fluid
The capacity of the hydraulic fluid tank is 151 L (40 gallons).
Parts, tools, and materials
Do this task when the pump is not running.
Do this every work shift.
2
1
3
1 Filler-breather cap
2 Sight gauge
3 Drain valve
Standard screwdriver
Do not put too much hydraulic fluid in the tank.
Antiwear (AW) mineral oil or synthetic hydraulic
fluid, ISO viscosity grade (VG) 32 or 46
Recommended materials
Clean funnel