Installation
212 811390 Operator Manual DynaMAX 550P/560P/575P Waterjet Pump
Stop Procedure Timers
Stop After Idle The pump is idle when the intensifier stops stroking.
When this feature is on, the pump turns off after the idle duration timer expires.
Cooling After Idle When this feature is on, the pump goes into cooling mode after the idle duration
timer expires.
Idle Duration This timer determines how long the pump is idle before it turns off or goes into
cooling mode.
The default is 10 minutes.
Stop Boost Pump This timer determines how long the pump is idle before the boost pump turns off.
The default is 180 seconds.
LP Drain Valve This timer determines how long after the pump turns off the low-pressure (LP)
drain valve opens and releases the low-pressure water from the system.
The default is 30 seconds.