EasyManuals Logo
Home>IBM>Server>iSeries 800

IBM iSeries 800 User Manual

IBM iSeries 800
622 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #319 background imageLoading...
Page #319 background image
The following table gives the components available for callout on the FC 5088, FC 0588 Expansion I/O
Unit. It matches those components with the FRU containing the the component. The other columns give
location information, CCIN information, a link to a remove and replace procedure, and additional
comments.
Table 1. FRU locations and failing components for FC 5088, FC 0588 Expansion I/O Unit
Possible failing
component
FRU
name Position
Type or CCIN
number (see the
Type, model, and
part number list)
Remove and replace
procedure Additional comments
v SPCN
v Card enclosure
or backplane
v Multi-adapter
bridge (all)
Tower card CB1 28B8 (See page
528)
See FC 5078, FC 0578,
FC 5088, FC 0588 -
Tower card - CB1
IOP PCI card C01
through
C03, C05
through
C08, C11
through
C14
2842 (See page
527), 2843 (See
page 527), or
2844 (See page
527)
See FC 5078, FC 0578,
FC 5088, or FC 0588 -
Cards (concurrent)
IOA PCI card C02
through
C04, C06
through
C09, C12
through
C15
See the Type,
model, and part
number list
See FC 5078, FC 0578,
FC 5088, or FC 0588 -
Cards (concurrent)
Analyze hardware problems 307

Table of Contents

Other manuals for IBM iSeries 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 800 and is the answer not in the manual?

IBM iSeries 800 Specifications

General IconGeneral
BrandIBM
ModeliSeries 800
CategoryServer
LanguageEnglish

Related product manuals