Possible failing
component
FRU
name Position
Type or CCIN
number (see the
Type, model, and
part number list)
Remove and replace
procedure Additional comments
Integrated
xSeries
(TM)
Server
(IXS)
PCI card C01, C05,
or C11
2890 (See page
527) or 2892 (See
page 527)
See FC 5078, FC 0578,
FC 5088, or FC 0588 -
Cards (dedicated)
If IXS in C01, C02 is
empty - if 2890 IXS, only
a short card can be in
C03.
If IXS in C05, C06 is
empty - if 2890 IXS, only
a short card can be in
C07.
If IXS in C11, C12 is
empty - if 2890 IXS, only
a short card can be in
C13.
v High-speed link
I/O adapter
v PCI host bridge
adapter
HSL I/O
bridge
card
C10 2786 (See page
526), 2887 (See
page 527)
See FC 5078, FC 0578,
FC 5088, or FC 0588 -
Cards (concurrent)
Power supply Power
supply
P01, P02 See Final
assembly — FC
5078, FC 5088
See FC 5078, FC 0578,
FC 5088, FC 0588
Power supplies - P01
and P02
Air moving device
(AMD)
AMD B01, B02 See Final
assembly — FC
5078, FC 5088
See FC 5078, FC 0578,
FC 5088, FC 0588 - Air
moving device (AMD) -
B01 and B02
AMD controller
card
AMD
controller
card
BB1 See Final
assembly — FC
5078, FC 5088
See FC 5078, FC 0578,
FC 5088, FC 0588 - Air
moving device
controller card - BB1
Display panel Display
panel
NB1 See the Type,
model, and part
number list
See FC 5078, FC 0578,
FC 5088, FC 0588
Display panel - NB1
HSL connection HSL cable HSL
cables on
the HSL
ports
See the Type,
model, and part
number list
See HSL cables -
concurrent
Notes:
1. The FC 5088, FC 0588 Expansion I/O Unit contains three system PCI busses.
2. In FC 5088 or FC 0588 Expansion I/O Unit, the bus numbers assigned to the busses are not required
to be in any order.
3. Card positions C01, C05 and C11 are required to be either I/O processors or Integrated xSeries
Servers (IXS).
4. J11 is an RPO connection, J14 is a uninterruptable power supply connector, J15 is an SPCN 1
connector, and J16 is an SPCN 2 connector.
5. Multi-adapter bridge domains are labeled PCI Bridge Set inside the tower.
6. The following table provides information necessary to identify the IOP to which IOAs are assigned.
v The left column indicates the domain in which IOA assignment is allowed.
308 Hardware (Remove and Replace; Part Locations and Listings)

Table of Contents

Other manuals for IBM iSeries 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 800 and is the answer not in the manual?

IBM iSeries 800 Specifications

General IconGeneral
BrandIBM
ModeliSeries 800
CategoryServer
LanguageEnglish

Related product manuals