EasyManuals Logo
Home>IBM>Server>pSeries 630 6C4

IBM pSeries 630 6C4 User Manual

IBM pSeries 630 6C4
651 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #366 background imageLoading...
Page #366 background image
Actions: This is an informational message. No action is required by the customer or service
representative.
2526: Informational message.
Actions: This is an informational message. No action is required by the customer or service
representative.
35EF: The scan dump code was not able to successfully complete the request to close the connection to
the load source.
Actions: This is an informational message. No action is required by the customer or service
representative.
9900: Memory allocation failure during firmware update.
Actions:
1. Reset the system using the pin-hole reset button on the operator panel. Retry the operation
that caused this error code.
2. Check for a later level of firmware than the one that you were trying to install. Apply if
available.
3. Call service support.
9901: State sequence error found during CRC query during firmware update.
Actions:
1. Reset the system using the pin-hole reset button on the operator panel. Retry the operation
that caused this error code.
2. Check for a later level of firmware than the one that you were trying to install. Apply if
available.
3. Call service support.
9902: Mailbox LID data failure during firmware update.
Actions:
1. Reset the system using the pin-hole reset button on the operator panel. Retry the operation
that caused this error code.
2. Check for a later level of firmware than the one that you were trying to install. Apply if
available.
3. Call service support.
9903: State sequence error found after a firmware update LID was received during firmware update.
Actions:
1. Reset the system using the pin-hole reset button on the operator panel. Retry the operation
that caused this error code.
2. Check for a later level of firmware than the one that you were trying to install. Apply if
available.
3. Call service support.
9904: Error while flashing an update LID during firmware update.
Actions:
1. Reset the system using the pin-hole reset button on the operator panel. Retry the operation
that caused this error code.
2. Check for a later level of firmware than the one that you were trying to install. Apply if
available.
3. Call service support.
9905: CRC mismatch after a firmware update LID was received during firmware update.
346 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide

Table of Contents

Other manuals for IBM pSeries 630 6C4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM pSeries 630 6C4 and is the answer not in the manual?

IBM pSeries 630 6C4 Specifications

General IconGeneral
BrandIBM
ModelpSeries 630 6C4
CategoryServer
LanguageEnglish

Related product manuals