SCSI IDs and Bay Locations
Note: To show the disk drive and disk drive bay locations, the pSeries 630 Model 6C4 and Model 6E4 are
shown with their bezels removed.
Index Bay Location Drive Name SCSI ID
1 Operator Panel
2 D01 IDE CD-ROM (Default)
or IDE DVD-ROM (Optional)
IDE (Non-SCSI)
SCSI ID 1
3 D02
Tape Drive (Optional) SCSI ID 0
SCSI DVD-RAM (Optional) SCSI ID 1
Diskette Drive (Optional) Not Applicable
4 D10 Disk Drive SCSI ID 8
5 D11 Disk Drive SCSI ID 9
6 D12 Disk Drive SCSI ID 10
7 D13 Disk Drive SCSI ID 11
Notes:
1. The SCSI bus IDs are the recommended values and indicate how the IDs are set when the system is
shipped from the factory. Field installations might not comply with these recommendations.
2. Media bay location D02 is designed to house one of the following optional devices:
v Tape Drive
v SCSI DVD-RAM
v Diskette Drive
20 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide