Selecting the Spanning Tree Enabled menu allows you to enable or disable the spanning tree flag. If this
flag is enabled (because the network the system is being attached to supports spanning trees), the
firmware will impose a waiting period of 60 seconds before the adapter is allowed to communicate with the
network. If this flag is disabled, the network adapter will be able to access the network immediately after
the system is connected.
Spanning Tree Enabled
10/100 Mbps Ethernet PCI Adapter II: U0.1-P1/E1
1. Yes <===
2. No
--------------------------------------------------------------------------------------------------
Navigation keys:
M = return to main menu
ESC key = return to previous screen X = eXit System Management Services
--------------------------------------------------------------------------------------------------
Type the number of the menu item and press Enter or Select a Navigation key: _
The Protocol option allows you to set the appropriate protocol for your network as shown below.
Protocol
10/100 Mbps Ethernet PCI Adapter II: U0.1-P1/E1
1. Standard <===
2. IEEE802.3
--------------------------------------------------------------------------------------------------
Navigation keys:
M = return to main menu
ESC key = return to previous screen X = eXit System Management Services
--------------------------------------------------------------------------------------------------
Type the number of the menu item and press Enter or Select a Navigation key: _
Select the ping test option from the network parameters menu to test an adapter’s network connection to
a remote system. After the ping test option is selected, the same series of screens will take you through
setting up the IP parameters and the adapter configuration before attempting the ping test.
Notes:
1. After the ping test is initiated, it may take 60 seconds or longer to return a result.
2. If the ping test passes or fails, the firmware will stop and wait for a key to be pressed before
continuing.
412 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide

Table of Contents

Other manuals for IBM pSeries 630 6C4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM pSeries 630 6C4 and is the answer not in the manual?

IBM pSeries 630 6C4 Specifications

General IconGeneral
BrandIBM
ModelpSeries 630 6C4
CategoryServer
LanguageEnglish

Related product manuals