Chapter 1. Start Service 1-15
Drive Error Codes
00F8
Sensor error #7.
During blink check, a Y
encoder sensor error was
detected.
CHK 00F8
1. Cycle the power and try again.
2. Replace the Library Control Blade (page 9-8).
3. Replace the Accessor assembly (page 9-23).
4. Replace the Accessor Flat Cable Plate assembly (page 9-28).
5. Replace the Back Board assembly (page 9-37).
6. Replace the TS3400 Tape Library chassis (page 9-44).
00F9
Sensor error #8.
During blink check, an X
encoder sensor error was
detected.
CHK 00F9
00FA
Sensor error #9.
During blink check, an
I/O slot sensor error was
detected.
CHK 00FA
00FB
Sensor error #10.
During blink check, a
magazine (Upper) sensor
error was detected.
CHK 00FB
00FC
Sensor error #11.
During blink check, a
magazine (Lower) sensor
error was detected.
CHK 00FC
00FD
Sensor error #12.
During blink check, an X
origin sensor error was
detected.
CHK 00FD
Table 1-2. Drive error codes
Code (H) Description
Panel
indication
Action Required
0200
Invalid data was sent to
Drive #1.
NAK was detected.
CHK 0200
1. Confirm the drive connection.
2. Cycle the power and try again.
3. Replace the Library Control Blade (page 9-8).
4. Replace the drive canister (page 9-11).
5. Replace the Drive Docking Card (page 9-19).
6. Replace the Back Board assembly (page 9-37).
7. Replace the TS3400 Tape Library chassis (page 9-44).
0201
A timeout error occurred
while waiting for response
from Drive #1.
CHK 0201
0203 Drive #1 is disconnected. CHK 0203
0205 Drive #1 is busy. CHK 0205
0206
Drive #1 failed to execute
a command because drive
could not be mounted.
CHK 0206
Table 1-1. Library error codes (continued)
Code (H) Description
Panel
Indication
Action Required