108 IBM System x3850 X6 and x3950 X6 Planning and Implementation Guide
4.1 Physical and electrical specifications
The x3850 X6 and x3950 X6 servers have the following physical, electrical, and
environmental specifications:
x3850 X6 dimensions:
– Height: 173 mm (6.8 in)
– Width: 482 mm (19.0 in)
– Depth: 804 mm (31.6 in)
– Depth with cable management brackets installed: 836 mm ( 32.9”)
– Depth with Full-length I/O Book installed: 921 mm (36.2 in)
x3950 X6 dimensions:
– Height: 351 mm (13.7 in)
– Width: 482 mm (19.0 in)
– Depth: 804 mm (31.6 in)
– Depth with cable management brackets installed: 836 mm ( 32.9”)
– Depth with Full-length I/O Book installed: 921 mm (36.2 in)
x3850 X6 weight:
– Minimum configuration: 35.9 kg (79.2 lb)
– Typical: 46.4 kg (102.3 lb)
– Maximum: 54.7 kg (120 lb)
x3950 X6 weight:
– Minimum configuration: 84.5 kg (186.3 lb)
– Typical: 88.2 kg (194.5 lb)
– Maximum: 110.0 kg (242.6 lb)
Air temperature support:
– Server on: 5 - 40 °C (41 - 104 °F); altitude: 0 to 3,050 m (10,000 ft).
– Server off: 5 - 45 °C (41 - 113 °F); altitude: 0 to 3,050 m (10,000 ft).
– Shipment: -40 - 60 °C (-40 - 140 °F)
Humidity support:
Server on: 8% to 85%, maximum dew point 24 °C
Server off: 8% to 85%, maximum dew point 27 °C
Electrical: Models with 1400 W AC power supplies:
– 100 to 127 Vac; 50 Hz or 60 Hz; 10 A (900 W DC output)
– 200 to 240 Vac; 50 Hz or 60 Hz; 8 A (1400 W DC output)
– Input kilovolt-amperes (kVA) (approximately):
• Minimum configuration: 0.16 kVA
• Maximum configuration: 3.2 kVA
Electrical: Models with 900 W AC power supplies:
– 100 to 127 Vac; 50 Hz or 60 Hz; 10.7 A
– 200 to 240 Vac; 50 Hz or 60 Hz; 5.3 A
– Input kilovolt-amperes (kVA) (approximately):
• Minimum configuration: 0.16 kVA
• Maximum configuration: 2.0 kVA
Electrical: Models with 750 W DC power supplies:
– -40 to -75 Vdc
– Input kilovolt-amperes (kVA) (approximately):
• Minimum configuration: 0.16 kVA