13-4
DD
Command table (continued)
13
CONTROL COMMAND
14 1D + Level data [SCAN SPEED] setting
(0=max. CCW to 255=max. CW)
1E + Level data [SCAN DELAY] setting
(0=max. CCW to 255=max. CW)
15 01 Read squelch status
02 Read signal (S-meter) level
03+Sign+M-type Read signal (dB meter) level
Sign: 0/1=+/–, M-type 0/1/2=dBµ,
dBµ[EMF], dBm
04 Read center meter level
16 02 Preamp (0=OFF; 1=preamp 1;
2=preamp 2)
12 AGC selection (0=OFF; 1=Fast;
2=Mid; 3=Slow)
22 Noise blanker
(0=OFF, 1=NB1, 2=NB2)
32 Audio peak filter (APF type is
SHARP; 0=OFF, 1=320 Hz,
2=160 Hz, 3=80 Hz), (APF type is
SOFT; 0=OFF, 1=WIDE, 2=MID,
3=NAR)
40 Noise reduction (0=OFF; 1=ON)
41 Auto notch (0=OFF; 1=ON)
43 Tone squelch (0=OFF; 1=ON)
48 Manual notch1 (0=OFF; 1=ON)
4A AFC (0=OFF; 1=ON)
4B DTCS squelch (0=OFF; 1=ON)
4C VSC (0=OFF; 1=ON)
4D Manual AGC (0=OFF; 1=ON)
4F Twin peak filter (0=OFF; 1=ON)
50 Dial lock (0=OFF; 1=ON)
51 Manual notch2 (0=OFF; 1=ON)
52 P25 Digital squelch
(0=OFF; 1=NAC, 2=SEL)
19 00 Read the receiver information
1A 00 Send/read memory contents (see
p. 13-10 for details)
03 Send/read the selected filter width
(AM: 0=200 Hz to 49=10 kHz;
SSB, CW: 0=50 Hz to 40=3600 Hz;
FSK: 0=50 Hz to 31=2700 Hz)
04 Send/read the selected AGC time
constant (AM: 0=OFF, 1=0.3 sec.
to 13=8.0 sec., SSB, CW, FSK:
0=OFF, 1=0.1 sec. to 13=6.0 sec.)
050001 Send/read FM Tone (Bass) level
(0=–15 to 30=+15)
050002 Send/read FM Tone (Treble) level
(0=–15 to 30=+15)
050003 Send/read WFM Tone (Bass)
level (0=–15 to 30=+15)
050004 Send/read WFM Tone (Treble)
level (0=–15 to 30=+15)
050005 Send/read AM Tone (Bass) level
(0=–15 to 30=+15)
050006 Send/read AM Tone (Treble) level
(0=–15 to 30=+15)
050007 Send/read SSB Tone (Bass) level
(0=–15 to 30=+15)
050008 Send/read SSB Tone (Treble)
level (0=–15 to 30=+15)
050009 Send/read CW Tone (Bass) level
(0=–15 to 30=+15)
050010 Send/read CW Tone (Treble) level
(0=–15 to 30=+15)
1A 050011 Send/read FSK Tone (Bass) level
(0=–15 to 30=+15)
050012 Send/read FSK Tone (Treble)
level (0=–15 to 30=+15)
050013 Send/read De-emphasis (FM 50k)
(0=OFF, 1=ON)
050014 Send/read De-emphasis (FM 15k)
(0=OFF, 1=ON)
050015 Send/read De-emphasis (FM 7k)
(0=OFF, 1=ON)
050016 Send/read AF high-cut filter (FM
50k) (0=OFF, 1=ON)
050017 Send/read AF high-cut filter (FM
15k) (0=OFF, 1=ON)
050018 Send/read AF high-cut filter (FM
7k) (0=OFF, 1=ON)
050019 Send/read AF high-cut filter
(WFM) (0=OFF, 1=ON)
050020 Send/read AF high-cut filter (AM)
(0=OFF, 1=ON)
050021 Send/read AF high-cut filter (SSB)
(0=OFF, 1=ON)
050022 Send/read AF high-cut filter (CW)
(0=OFF, 1=ON)
050023 Send/read AF high-cut filter (FSK)
(0=OFF, 1=ON)
050024 Send/read AF high-cut filter (P25)
(0=OFF, 1=ON)
050025 Send/read speech level
(0=0% to 255=100%)
050026 Send/read beep gain
(0=0% to 255=100%)
050027 Send/read beep gain limit
(0=OFF, 1=ON)
050028 Send/read headphones output
ratio (0=0.60 to 255=1.40)
050029 Send/read SPEECH OUTPUT
level (0=0% to 255=100%)
050030 Send/read S/P DIF output level
(0=0% to 255=100%)
050031 Send/read REC REMOTE output
(0=OFF, 1=ON)
050032 Send/read external meter output
selection
(0=Signal, 1=Signal+SQL)
050033 Send/read external meter output
level
(0=0% to 255=100%)
050034 Send/read reference signal in/out
setting (0=IN, 1=OFF, 2=OUT)
050035 Send/read reference signal fre-
quency setting
(0=0% to 255=100%)
050036 Send/read screen image type
(0=A, 1=B)
050037 Send/read signal meter type (0=S,
1=dBµ, 2=dBµ[EMF], 3=dBm
050038 Send/read meter peak hold set
(0=OFF, 1=ON)
050039 Send/read memory name indica-
tion setting (0=OFF, 1=ON)
050040 Send/read audio peak filter width
pop-up indication setting
(0=OFF, 1=ON)
050041 Send/read manual notch width
pop-up indication setting
(0=OFF, 1=ON)
Command Sub command Description Command Sub command Description