5 System Commissioning
-
159
-
5.5 Commissioning at Normal Speed
Shaft auto-
tuning
Car top
commissioning
Make preparations.
Check that shaft auto-tuning
conditions are met.
Perform shaft auto-tuning.
Commissioning
at normal
speed
Perform running test at normal
speed.
Light curtain
commissioning
Door machine
controller
commissioning
HCB commissioning
HCB installation
HCB address setting
5.5.1 Shaft Auto-tuning
1 Make preparations for shaft auto-tuning.
1.
Check that the shaft switches act properly.
2.
Check that the acting sequence of the
leveling switches is correct.
I
ncluding final limit switches, limit switches, slowdown switches
, and leveling switches.
3. Check CANbus communication state.
Acting sequence of sensors at inspection up: up leveling switch → door zone switch → down leveling switch
Acting sequence of sensors at inspection down: down leveling switch → door zone switch → up
leveling switch
Check CANbus communication state. If fault E51
is not reported and the CAN1 indicator on the
MCB is
steady ON, it indicates that CANbus communication between the MCB and the CTB is normal. If CANbus
communication is abnormal, rectify fault E51 according to the solution described in section 7.4.
Generally,
one leveling switch is installed. If multiple leveling switches are installed,
check that the acting
sequence is correct. Take the situation with three sensors as an example:
switch
Parameters
Parameters
Parameter
Description
Description Default Remarks
F0-04
Rated elevator
speed
 1.600 m/s -
F6-00
󶍿
elevator
F6-01 to F6-56 9
󶍿
󶍿
F6-01
󶍿
elevator
1 to F6-00 1 -
F3-26
Shaft auto-tuning
speed
0.250 to 0.630 0.250 -
NOTE
After F0-04 is changed, shaft auto-tuning must be performed again.
Otherwise, an abnormality will occur during elevator running.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance Monarch NICE 3000 new Series and is the answer not in the manual?

Inovance Monarch NICE 3000 new Series Specifications

General IconGeneral
BrandInovance
ModelMonarch NICE 3000 new Series
CategoryController
LanguageEnglish

Related product manuals