6 Parameter Description
-
253
-
Group FE: Display setting parameters
Function
Code
Name Setting Range Default Unit Property
FE-00 Collective selective mode 0 to 2 0 -
★
It is used to set the collective selective mode of the system. The values are as follows:
■
0: Full collective selective
The elevator responds to both up and down hall calls.
■
1: Down collective selective
The elevator responds to down hall calls but does not respond to up hall calls.
■
2: Up collective selective
The elevator responds to hall up calls but does not respond to hall down calls.
Function
Code
Name Setting Range Default Unit Property
FE-01 Floor 1 display
00: Display "0"
01: Display "1"
02: Display "2"
03: Display "3"
04: Display "4"
05: Display "5"
06: Display "6"
07: Display "7"
08: Display "8"
09: Display "9"
10: Display "A"
11: Display "B"
12: Display "G"
13: Display "H"
14: Display "L"
15: Display "M"
16: Display "P"
17: Display "R"
18: Display "-"
19: No display
20: Display
"12"
21: Display
"13"
22: Display
"23"
23: Display "C"
24: Display "D"
25: Display "E"
26: Display "F"
27: Display "I"
28: Display "J"
29: Display "K"
30: Display "N"
31: Display "O"
32: Display "Q"
33: Display "S"
34: Display "T"
35: Display "U"
36: Display "V"
37: Display "W"
38: Display "X"
39: Display "Y"
40: Display "Z"
41: Display
"15"
42: Display
"17"
43: Display
"19"
1901 -
☆
FE-02 Floor 2 display 1902 -
☆
FE-03 Floor 3 display 1903 -
☆
FE-04 Floor 4 display 1904 -
☆
FE-05 Floor 5 display 1905 -
☆
FE-06 Floor 6 display 1906 -
☆
FE-07 Floor 7 display 1907 -
☆
FE-08 Floor 8 display 1908 -
☆
FE-09 Floor 9 display 1909 -
☆
FE-10 Floor 10 display 0100 -
☆
···
FE-31 Floor 31 display 0301 -
☆
FE-35 Floor 32 display 0302 -
☆
FE-36 Floor 33 display 0303 -
☆
FE-37 Floor 34 display 0304 -
☆
FE-38 Floor 35 display 0305 -
☆
FE-39 Floor 36 display 0306 -
☆
FE-40 Floor 37 display 0307 -
☆
FE-41 Floor 38 display 0308 -
☆
FE-42 Floor 39 display 0309 -
☆
FE-43 Floor 40 display 0400 -
☆