2 Installation and Wiring
-
38
-
2.1 Installation
2.1.1 Installation Environment Requirements
󶙽Environment requirements
Item Requirement
Altitude
Below 1000 m; de-rated by 1% for each 100 m higher if the altitude is above
1000 m; maximum 3000 m.
Ambient
temperature
-10ºC to 50ºC; air temperature change of less than 0.5
ºC
/min; rated current
derated by1.5% for each 1
ºC
higher if the ambient temperature is above 40ºC;
maximum temperature 50
ºC
Storage
temperature
-40ºC to 60ºC
Ambient
humidity
Less than 95% RH, non-condensing
Storage
humidity
Less than 95% RH, non-condensing
Vibration
and shock
Sinusoidal vibration: 5.9 m/s
2
(0.6 g) at 2-200 Hz
IP level IP20
Heat
dissipation
and
ventilation
󶎀
space around for heat dissipation.
Mounting
location
Free from direct sunlight
Free from over 95% humidity and condensation
Free from corrosive, explosive and combustible gas
Free from oil dirt, dust and metal powder
󶙮
Protective
enclosure
󶍾
󶍾
protection, and satisfy the regional laws & regulations and related IEC
requirements.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance Monarch NICE 3000 new Series and is the answer not in the manual?

Inovance Monarch NICE 3000 new Series Specifications

General IconGeneral
BrandInovance
ModelMonarch NICE 3000 new Series
CategoryController
LanguageEnglish

Related product manuals