Page #66 background image
2 Installation and Wiring
-
65
-
2.3.4 Modbus Communication
1 Hardware wiring
RS485 hardware connection
NICE3000
new
CN1
CN9
CN3
CN2
CN7
X1
X2
X3
X4
X5
X6
X7
X8
X9
X10
X11
X12
X13
X14
X15
X16
X17
X
18
X19
X20
X21
X22
X23
X24
Al-M
Al+
X25
X26
X27
XCOM
Y1
M1
Y2
M2
Y3
M3
Y4
M4
Y5
M5
Y6
M6
CN5
R
S
T
PRG
UP
SET
+
PB
U
V
W
J12
M24V
MOD1+
CAN1+
CAN1-
MOD1-
MCM
MCTC-HCB
24V
MOD-
MOD+
CN12
CN1
Top
floor
MCTC-PG
COM
MCTC-HCB
24V
MOD-
MOD+
CN1
COM
MCTC-HCB
24V
MOD-
MOD+
CN1
Bottom
floor
COM
CN4
CAN2-
CAN2+
CAN3-
MOD2+
MOD2-
XCOM
X28
CAN3-
+12V
MCM
󶙽 RS485 connection between the NICE3000