F8-14 Bit0 = 0: The communication baud rate between the MCB and HCB is 9600 bps.
F8-14 Bit0 = 1: The communication baud rate between the MCB and HCB is 38400 bps.
Note that only the NICE3000
new
product supports 38400 bps, and the NICE3000 sup-
ports only 9600 bps.
The system automatically determines the communication baud rate, and generally,
you need not set this parameter.
F8-16 is used to set the HCB start address of the back door in opposite door mode.
but displays the set address of itself, convenient for inspection in the case of wrong
38400 bps.
Group F9: Time parameters
Function
Code
Name Setting Range Default Unit Property
F9-00
Idle time before returning
0 to 240 10 min
☆
When the idle time of the elevator exceeds the setting of this parameter, the elevator
Function
Code
Name Setting Range Default Unit Property
F9-01 Car energy-saving time 0 to 240 2 min
☆
-
cally.
the fan and lamp automatically after the time set in this parameter.
Function
Code
Name Setting Range Default Unit Property
F9-02
Motor running time
limit
0 to 45 45 s
★
It is used to set the running time limit of the motor.
In normal running state, if the continuous motor running time in the same direction
-
nal is received, the system will perform protection. This parameter is mainly used for
over-time protection in the case of steel rope slipping on the traction sheave.