5 System Commissioning
-
166
-
5.5.3 HCB Installation and Setting
This section describes HCB installation and setting of the single-door independent
elevator system. For details on HCB installation and setting of parallel elevator system
and opposite door elevator system, refer to related sections.
1 HCB installation
shown in Figure 5-14.
The HCB communicates with the MCB via Modbus. All HCBs are connected in parallel
and then connected to the MCB.
2 HCB address setting
Set an address for each HCB. Otherwise, the HCB cannot be used.
The address of each HCB must be unique. HCBs with the same address cannot be
used. For details on how to set the address, see the description of the corresponding
HCB.
Leveling plate 1
Floor 1
Floor 2
Floor 3
Floor 4
Leveling plate 2
Leveling plate 3
Leveling plate 4
(Non-service floor,
HCB not installed)
1
2
4
HCB address: 1
HCB address: 2
HCB address: 4
HCB installation and address setting
After completing HCB installation and address setting, you can call the elevator by
using the HCB to start normal-speed running.
◆
When the display board is used inside the car, the address must be set to 0.