EasyManuals Logo
Home>Inovance>Controller>Monarch NICE 3000 new Series

Inovance Monarch NICE 3000 new Series User Manual

Inovance Monarch NICE 3000 new Series
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #226 background imageLoading...
Page #226 background image
6 Parameter Description
-
225
-
Group F7: Test function parameters
The parameters in this group are provided to facilitate elevator commissioning.
Before the elevator running test at normal speed is performed, check that the shaft is
󶍿
󶍿
󶍿
completed, check whether the parameters in this group are set correctly.
Function
Code
Name Setting Range Default Unit Property
F7-00 󶍿 0 to F6-00 0 -
F7-01 󶍿 0 to F6-00 0 -
F7-02
󶍿
registered
0 to F6-00 0 -
󶍿
repairing. They can be respectively used as the car call button, hall call up button and
hall call down button. After the test parameters are set, the calls remain valid, and will
󶍽
Function
Code
Name Setting Range Default Unit Property
F7-03 Random running times 0 to 60000 0 -
F7-03 is used to set the random running times of the system.
The NICE3000
new
has the random automatic running function. If the setting of F7-03 is
greater than 60000, the system keeps implementing random automatic running until
you set F7-03 to 0. You can set the time interval between two times of random running
in F7-08.
Function
Code
Name Setting Range Default Unit Property
F7-04 Hall call enabled
0: No
1: Yes
0 -
F7-04 is used to forbid the hall calls. The values are as follows:
0: No (hall call allowed)
1: Yes (hall call forbidden)
Function
Code
Name Setting Range Default Unit Property
F7-05 Door open enabled
0: No
1: Yes
0 -
F7-05 is used to forbid door open. The values are as follows:
0: No (door open allowed)
1: Yes (door open forbidden)
NOTE
Note that continuous running of the elevator without opening the door
accelerates overheating of the controller module. Long-time use in such
mode may cause overheat protection, and therefore, use the function with
caution.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance Monarch NICE 3000 new Series and is the answer not in the manual?

Inovance Monarch NICE 3000 new Series Specifications

General IconGeneral
BrandInovance
ModelMonarch NICE 3000 new Series
CategoryController
LanguageEnglish

Related product manuals