6 Parameter Description
-
224
-
Function
Code
Name Setting Range Default Unit Property
F6-49
Evacuation parking
0 to F6-00 0 s
★
in F6-49.
Function
Code
Name Setting Range Default Unit Property
F6-50 0 to 40 0 -
★
-
tent. Direct parallel control can be implemented by setting this parameter, without the
Function
Code
Name Setting Range Default Unit Property
F6-51 Static current 0.00 to 655.00 0 A
★
Function
Code
Name Setting Range Default Unit Property
F6-52
Program function
selection
0 to 65535 0 -
★
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the
function is disabled.
-
lowing table.
F6-52 Program function selection
Bit Function Description Default
Bit2
Bit2: CAN
communication AFE
support
It is used to enable the AFE communication function. 0
Bit6
CAN
communication
leveling signal
It is used to enable the transmission of up
leveling and down leveling signals via CTB CAN
communication.
0
Bit7
Door machine
overheat detection
It is used to enable the door machine overheat
detection function.
0