9 Description of Functions and Schemes
-
333
-
2) HCB setting
24V
COM
MOD+
MOD-
NICE3000
new
controller
CN3
HCB of front door HCB of back door
Address: 1
Address: X
Address
:
20
Address:
N + 1
Address:
N + X
Address:
N + 20
Floor
20
Floor X
Floor 1
HCB setting diagram 1
■
HCB addresses of front door: 1 to 20
■
HCB address of back door: N to N+20
,
3 Parameters
Type
Door Control
Mode
Parameter Setting
Service
Floor
Operation
Box CCB
Wiring
HCB
Address
Setting
Mode
Selection
Other
Parameters
Mode 1
Simultaneous
control
FC-04 = 0
FB-00 =
2 (CTB
analog
input)
F8-16 = N
20
The CCB of
front door is
connected
to CN7 on
the CTB.
The CCB of
back door is
connected
to CN8 on
the CTB.
HCB
address
of front
door:
HCB
address
of back
door: N to
N+20
Mode 2
Hall call
independent,
car call
simultaneous
FC-04 = 1
Same as
mode 1
20
Mode 3
Hall call
independent,
car call manual
control
FC-04 = 2 (CTB
analog input)
F6-40 Bit4 = 1
Same as
mode 1
20
Mode 4
Hall call
independent,
car call
independent
FC-04 = 3
Same as
mode 1
20
In mode 3, the car door to open is controlled as follows:
◆
Control by button
Connect the button to JP16 on the CCB, and set F6-40 Bit2 to 1. When the button indicator is
steady ON, only the front door opens; when the button indicator is steady OFF, only the back
door opens.
◆
Control by switch
Connect the switch to JP20 on the CCB, and set F6-40 Bit15 to 1. When JP20 is ON, only the
front door opens; when JP20 is OFF, only the back door opens.