SOURce Subsystem
Copyright © Itech Electronic Co., Ltd. 92
input is turned off.
NOTE: Use POW:PROT:DEL to prevent momentary power limit conditions
caused by programmed changes from tripping the overpower
protection.
Command Syntax
[SOURce:]POWer:PROTection[:LEVel] <NRf+>
Parameters
0 through MAX | MINimum | MAXimum | DEFault
Unit
W (power)
*RST Value
MAXimum
Examples
POW:PROT 100
Query Syntax
[SOURce:]POWer:PROTection[:LEVel]? [ MINimum | MAXimum | DEFault ]
Returned Parameters
<NR3>
Related Commands
POW:PROT:DEL
[SOURce:]POWer:PROTection:DELay
This command specifies the time that the input power can exceed the
protection level before the input is turned off.
Command Syntax
[SOURce:]POWer:PROTection:DELay <NRf+>
Parameters
0 to 60 seconds | MINimum | MAXimum | DEFault