SCPI Measurement Command
Copyright © Itech Electronic Co., Ltd. 52
Chapter7 SCPI Measurement Command
FETCh:VOLTage[:DC]?
This command is used to get the latest measured DC voltage.
MEASure:VOLTage[:DC]?
This command initiates and executes a new voltage measurement, and returns
the measured input voltage of the electronic load.
Command Syntax
FETCh:VOLTage[:DC]?
MEASure:VOLTage[:DC]?
Parameters
None
Examples
FETC:VOLT?
Returned Parameters
<NRf>
FETCh:VOLTage:MAX?
This command is used to read the max voltage of the latest measurement.
MEASure:VOLTage:MAX?
This command initiates and executes a new maximum voltage measurement,
and returns the measured input maximum voltage of the electronic load.
Command Syntax
FETCh:VOLTage:MAX?
MEASure:VOLTage:MAX?
Parameters
None